It is unlikely that all microswitches have failed at the same time. Beneath the taps you will find the wires that connect to the microswitches. If you disconnect or cut these wires beneath one of the taps and join the two wires together then this will by pass the microswitch and the pump should run. If the pump fails to operate then you must look at the pump itself or check the wiring.