Protective Covers
If you have checked the fuses it is likely that the electric pump has failed and will need to be replaced. Remove the blue operating button to access two screws. Remove the screws and lift the assembly ( held only by mastic ) to access the switch and pump. Before changing the pump make sure that you have continuity through the switch when depressed. If no continuity then the switch may be at fault. If you do have continuity then replace the pump. Replacement pump is our part 229418.
Switch part is 237090